banner
Translational thermal shock test chamberTranslational thermal shock test chamber

Translational thermal shock test chamber

产品详情

product name

Translational thermal shock test chamber

model

TS-1000L

TS-2000L

TS-10000L

Nominal internal volume (L)

1000

2000

10000

Inner box size (mm)

Width

1000

1500

3500

depth

1000

1400

3500

height

1000

1000

800

Basket size (mm)

Based on actual design

About 3500×3500×800   W×D×H(mm)

Outer box size (mm)

Based on actual design

About 10000×4500×1950  W×D×H(mm)

performance parameter 

 

 

Energy storage temperature range

-75~200℃*3

Energy storage temperature range in high temperature zone:+60 ℃~160 ℃

Low temperature range: -10 ℃ to -60 ℃


Impact temperature range

+60℃~125℃/-65℃~-10℃

+60℃~125℃/-40℃~-10℃

Temperature deviation

≤±2℃

Test at a constant temperature of ≤± 2 ℃

Temperature fluctuations

≤±0.5℃

Test at a constant temperature of ≤± 0.5 ℃

test method

Horizontal movement of basket to switch temperature zone * 2

Horizontal movement of basket to switch temperature zone * 2

Basket conversion time

10S

15S

Temperature recovery time

≤5min

≤5min, no-load

Exposure time at room temperature

≥15min

High temperature exposure+150 ℃, for more than 30 minutes

Low temperature exposure to -40 ℃ for more than 30 minutes

refrigeration system

Cooling method

Mechanical compression cascade refrigeration method

Two level stacked system

compressor

Semi closed mechanical compressor

German Bitzer Compressor/American Carrier/German Blog

Cooling method

water-cooling

Water cooling (over 50 tons)

control system

controller

TFT true color touch screen controller, fixed value or program running

input

Touch screen input, switching between Chinese and English

power supply

380±10%(v);34;50Hz±10%


Installed power (KW)

82KW

110KW

Maximum cooling power 92KW

The maximum heating power of the high-temperature tank is 60KW

The maximum heating power of the low-temperature tank is 24KW

The maximum operating power is approximately 130KW (subject to final design)

Maximum operating current 230A


Weight (KG)

2470㎏

2980㎏

About 3200kg, occupying an area of approximately 45m ²

热门标签 :

Copyright: Guangzhou Yama Intelligent Instrument Co., Ltd

IPv6 network supported

top