Welcome to our website.
product name | Temperature range (℃)Humidity range (% RH) | ||||||||||||
model | YK-225 | YK-408 | YK-608 | YK-1000 | YK-225 | YK-408 | YK-608 | YK-1000 | YK-225 | YK-408 | YK-608 | YK-1000 -7OW20 | |
Internal volume (L) | 225 | 408 | 608 | 1000 | 225 | 408 | 608 | 1000 | 225 | 408 | 608 | 1000 | |
inside dimensions(mm) | W | 600 | 800 | 800 | 1100 | 600 | 800 | 800 | 1100 | 600 | 600 | 800 | 1100 |
H | 850 | 850 | 950 | 950 | 850 | 850 | 950 | 950 | 850 | 850 | 950 | 950 | |
D | 450 | 600 | 800 | 950 | 450 | 600 | 600 | 950 | 450 | 800 | 800 | 950 | |
Outer box size (mm) | W | 800 | 1000 | 1000 | 1300 | 800 | 900 | 1400 | 1700 | 800 | 800 | 1400 | 1700 |
H | 1970 | 1970 | 2070 | 2070 | 1970 | 1970 | 2070 | 2070 | 1970 | 1970 | 2070 | 2070 | |
D | 1800 | 1850 | 2050 | 2200 | 2000 | 2250 | 2550 | 2900 | 2200 | 2550 | 2750 | 2900 | |
(-70~150)℃ | |||||||||||||
(20~98)%RH(20~85)℃ | |||||||||||||
Temperature fluctuation (℃) | ±0.5℃ | ||||||||||||
Temperature deviation (℃) | ±2.0℃ | ||||||||||||
Humidity deviation (% RH) | ±3.0%RH(>75%RH)±5.0%RH(≤75%RH) | ||||||||||||
Heating and cooling rate (℃/min) | 10℃/min | 15℃/min | 20℃/min | ||||||||||
Temperature and humidity regulation method | BTHC Balanced Temperature Control (SSR Humidity Control) Method | ||||||||||||
Usage environment | Temperature: (5~36) ℃ Humidity: (30~85)% RH Pressure: (86~106) kPa | ||||||||||||
material | Inner box | Stainless steel plate SUS304 | |||||||||||
Outer box | Double sided galvanized steel plate, surface treated with electrostatic spraying treatment | ||||||||||||
heat preservation | Fiber high-temperature cotton+polyurethane foam | ||||||||||||
actuator | fan | Extended shaft centrifugal fan | |||||||||||
refrigeration machine | Low noise piston compressor or scroll compressor | ||||||||||||
heater | Imported nickel chromium alloy electric heating wire | ||||||||||||
humidifier | 316 stainless steel humidifier (external steam generator) | ||||||||||||
Controller system | Touch screen+PLC | 7.0 ", 800x480 resolution, mixed output PLC | |||||||||||
Operation mode | Fixed value running, program running, timed running | ||||||||||||
Setting method | Simplified Chinese+English, touch input | ||||||||||||
Program capacity | 102 sets of programs, each set consisting of 96 segments, capable of setting 9999 loops, with the ability to connect programs | ||||||||||||
Setting Range | Adjust ± 5.0 ℃ and humidity range (5-100)% RH (humidity equipment) based on the maximum range value of equipment performance | ||||||||||||
display resolution | Temperature: 0.01 ℃, Humidity: 0.1% RH (humidity equipment), Time: s | ||||||||||||
sensor | PT100 (platinum resistance) | ||||||||||||
control mode | Low temperature cold balance+anti integral saturation P1D+self-tuning | ||||||||||||
Curve recording | Equipped with live data storage function, the screen can slide to browse data and capture images | ||||||||||||
additional function | Fault alarm and cause handling prompt function: timed power on/off, power-off protection, user permission function | ||||||||||||
communication | Support R5485, LAN (network port), convenient for remote monitoring, data collection: IBM PC compatible machine, P II or above CPU, 128MB or above memory, Simplified Chinese version operating system | ||||||||||||
data acquisition | 1. Equipped with a USB interface, it can save curve data for 3 months and download historical curves and data; 2. It can replace a recorder, with a built-in large storage space that can save data for 3 months after 24 hours of continuous startup. The sampling time is minutes, and it can replace computer storage. Users can export historical data from a USB flash drive (time optional) and generate CSV format files; 3. Connect to PC (optional) - Record test data through computer monitoring software, display curves, and use PC as a remote terminal to achieve remote monitoring. | ||||||||||||
| Water supply ª | Water supply method | Pump pumping | |||||||||||
| Water storage tank | 10L/20L/40L | ||||||||||||
| water quality | Electrical resistivity>500 Ω | ||||||||||||
Circulating water flow rate d (t/h) | 12 | 14 | 16 | 18 | 14 | 16 | 18 | 22 | 18 | 20 | 22 | 28 | |
Power supply (V)/(Hz) | AC voltage 380V ± 38V frequency 50z ± 0.5Hz three-phase four wire+grounding protection | ||||||||||||
Maximum current (A) | 45 | 50 | 55 | 63 | 60 | 75 | 90 | 120 | 75 | 100 | 160 | 190 | |
Power Supply (KW) | 25 | 28 | 32 | 37 | 45 | 45 | 62 | 84 | 45 | 68 | 110 | 130 | |
| Weight (kg) | 850 | 900 | 950 | 1050 | 950 | 1000 | 1100 | 1200 | 1000 | 1150 | 1300 | 1500 | |
| Standard configuration | 1 electric observation window, 1 ф 50 test hole on each side, 2 sets of sample racks, 4 casters | ||||||||||||
Safety device | Leakage switch, motor, compressor, phase sequence, over temperature, dry burning and other protection functions | ||||||||||||
classification
new product
Copyright: Guangzhou Yama Intelligent Instrument Co., Ltd

IPv6 network supported