banner
Walk in constant temperature and humidity laboratory (aging room)Walk in constant temperature and humidity laboratory (aging room)

Walk in constant temperature and humidity laboratory (aging room)

产品详情

product name

Walk in constant temperature and humidity laboratory (aging room)

model

YW-078

-40WX5LH

YW-117

-40WX5LH

YW-156

-40WX5LH

YW-162

-40WX5LH

YW-216

-40WX5LH

YW-270

-40WX5LH

YW-220

-40WX5LH

YW-294

-40WX5LH

YW-367

-40WX5LH

YW-441

-40WX5LH

Internal volume (L)

6.8/7.8

10.2/11.713.6/15.614.2/16.218.9/21.623.6/2719.36/2232.2/29.432.2/36.738.6/44.1

inside dimensions(mm)

W

180025003400

H

L-type: 2100/H-type: 2400

D

1800270036002700360045002700360045005400

Carton size(mm)

W

2000200020002000270027003600360036003600

H

L-type: 2400/H-type: 2700

D

Inner box size D+1205Inner box size 0+1355Inner box size D+1650
performanceTemperature range (℃)Minimum temperature: -10 ℃, -20 ℃, -30 ℃, -40 ℃, -50 ℃, -60 ℃, -65 ℃, maximum temperature:+85 ℃
Humidity range (% RH)(20~98)%RH(20~85)℃
Temperature fluctuation (℃)±0.5℃
Temperature deviation (℃)±2. 0℃
Humidity deviation (% RH)±3.0%RH(>75%RH)±5.0%RH(≤75%RH)
heating up time(25~85)℃
≤45min≤50min≤55min≤45min≤50min≤60min≤50min≤60min≤70min≤80min
Cooling time25 ℃~rated extreme low temperature
(30-180) min (varies depending on different models and configurations)
Temperature and humidity regulation methodBTC Balanced Temperature Control (SSR Humidity Control) Method
Usage environmentTemperature: (5~36) ℃ Humidity: (30~85)% RH Pressure: (86~106) kPa
Thermal insulation board structureSpray coated galvanized color steel plate - attached temperature stress insulation material - SUS304 stainless steel composite assembly plate

actuator

fan

Extended shaft centrifugal fan

refrigeration machine

Low noise piston compressor or scroll compressor

heater

Imported nickel chromium alloy electric heating wire
humidifier316 stainless steel humidifier (external steam generator)

Controller system

Touch screen+PLC

7.0 "or 10.0", 800X480 resolution, mixed output PLC

Operation mode

Fixed value running, program running, timed running

Setting method

Simplified Chinese+English, touch input

Program capacity

96 sets of programs, with 92 segments per set, capable of setting 9999 loops, and programs with linking function

Setting Range

Adjust ± 50 ℃ and humidity range (5-100)% RH (humidity equipment) based on the maximum range value of equipment performance

display resolution

Temperature: 0.01 ℃, Humidity: 0.1% RH (humidity equipment), Time: s

sensor

PT100 (platinum resistance)

control mode 

Low temperature cold balance+anti integral saturation PID+self-tuning

Curve recording

Equipped with live data storage function: can slide and browse data on the screen: capture function

additional function

Fault alarm and cause handling prompt function: timed power on/off, power-off protection, user permission function

communication

Supports communication through RS485, LAN (network port), GPRS (mobile phone) and other methods for convenient remote monitoring. According to data collection: IEM PC compatible machine, P II or above CPU, 128M or above memory, Simplified Chinese version operating system

data acquisition

1. Equipped with US8 interface, it can save curve data for 3 months and download historical curves and data;


2. It can replace a recorder, with a built-in large storage space that can save data for 3 months after 24 hours of continuous startup. The sampling time is minutes, and it can replace computer storage. Users can export historical data from a USB flash drive (time optional) and generate CSV format files;

3. Connect to PC (optional) - Record test data through computer monitoring software, display curves, and use PC as a remote terminal to achieve remote monitoring.


water supply

Water supply system

Equipped with multi-stage filtration reverse osmosis pure water machine or water pump lift

water quality

Electrification rate>500 Ω

Circulating cooling water

Water supply pressure: 0.25-0.4MPa Water temperature: ≤ 30 ℃

Power supply (V)

AC voltage 380V ± 38V frequency 50Hz ± 0.5Hz three-phase four wire+grounding protection

Power Supply (KW)

(20~55) kW (varies depending on different models and configurations)

Standard configuration

1 electric observation window, 1 ф 50 test hole on each side, 2 sets of sample racks, 4 casters

Safety device

Leakage switch, motor, compressor, phase sequence, over temperature, burning and other protection functions

热门标签 :

Copyright: Guangzhou Yama Intelligent Instrument Co., Ltd

IPv6 network supported

top